Troubles |
Cause |
Remedies |
After the pump startingno water i s drawn in. and the hands ofracuunl gauge and manometer beat heavily |
The water poured in
the pmnp is not enough Leakage of air is
found from the suction pipe |
Pour water into the
pump again Block the leaking
place |
The pump doesnt
draw any water but a high degree vacuum is indicated on the vacuum gauge |
The foot valve is
not opened The resistance of
suction is too high The suetion head is
too high |
Correct or renew
the foot valves Clean or renew the
suction pipe Make the suction
head lower |
No water is pumped
outBut high pressure is shown on the outlet nlanonleter |
The direction of
the rotation is not right The suction
resistance is too high The impeller flow
passage is clogged The revolutions is
not enough |
Change the
direction of the rotation Check the length of
the pipe Clean the impeller Increase the
revolutions |
Tile flow rate is
decreasing or the laead is low |
The impeller flow
passage or(inlet pipe and outlet pipe)in-out-let pipes are clogged The seal ring and
the impeller is worn out The running speed
of the pump is lower than the rated |
Clean tile impeller
and the pipe passage way Renew the worn
parts Increase the
revolutions |
Over consumption of
the pump power. |
Packing is too
tight The impeller is rubbed by double
suction seal ring The flow rate is
too large |
Loosen the packing
gland Clear out the mechanic
friction Turn the discharge
valve brake smaller |
Unexpected noises
are heard and 110 water is drawn |
The suction
resistance is too high The suction head is
too high Leakage of air
found from the suction pipe Error is found |
Check the pipe and
the foot valve Make the suction head
lower Block the leaking
place Adjust the use of
discharge breake valve in specific working condition |
The pump vibrates
heavily |
Error is found The impeller is not
balance Tile pump shaft is
not concentric with the motor. The nuts of
foundation are loose |
Clear out the error Correct impeller
static balance Screw the nuts of
the foot bolt tightly Correct tile
coaxial degree between pump and motor shaft |
The beating is
overheated |
The grease is not enough
or too much or goes bad The pump and the
motor shaft is not concentric |
Clean the bearing
and renew the oil Correct the pump
and the motor shaft coaxial degree |